2 In 1 RF Spider Vein Removal and Ice Hammer Machine
Product description
1. Treatment theory
The RF high frequency vascular removal machine uses professional painless high-frequency
technology, using micro-point high-frequency electric flash to generate 13.36 million Hz high-frequency
electromagnetic oscillations, using soft needle wire to conduct the released energy below the skin surface, at Shatter hemoglobin within 1000 seconds, break the hemoglobin in the blood vessels into small molecules and be absorbed by the skin tissue itself (hemoglobin has the function of carrying oxygen, making our capillaries appear red, and hemoglobin is destroyed After crushing, the oxygen molecules are released and the redness of the broken capillaries fades away instantly). The extremely high energy density of the instrument can instantly coagulate the hemoglobin and endothelial cells in the dilated capillaries, thereby immediately closing the dilated blood vessels and fundamentally treating the telangiectasia. Based on the skin's self-repairing and regenerating functions, the coagulated tissue will fall off within 3-7 days, regenerating new skin tissue, to achieve the effect of one-time eradication of spider vein.
2. Treatment scope of the RF machine
Remove all kinds of spider veins and vascular veins and thread-shaped veins from the body surface
3. Feature and description
* ASI space-grade HF / VHF power tube, no power loss during continuous operation.
* 13.56MHz ± 130V sine wave output, real high frequency, no sparks, no skin damage.
* Continuous or pulse dual output mode selection.
* No offset in different impedance environments.
* The output power is constant and there is no large-scale drift, which ensures the consistency of
operation.
* Professional treatment pen needles ensure immediate closure of blood capillaries and good protection of the epidermis.
* Configure imported core boards to ensure long life and stability.
4. The ice compress hammer
The ice compress hammer can be used after the instrument is powered on, regardless of the screen
program. As long as keep pressing the switch on the ice compress hammer, the longer the use time, the
lower the surface temperature of the ice compress hammer, and the lowest temperature value is maintained for about 20 minutes.
5. Parameter
Output voltage |
0V-130V±10% |
Output frequency |
13.56MHz |
Environment temperature |
25-45ºC |
Input power |
60W |
Output power |
45W |
Screen |
8 inch TFT color touch display |
Mode |
Pulse mode, continuous mode |
Detailed Images
Our Company
Started from Year 2009, Guangzhou Allfond Electronics Co.,Ltd is one of the most professional manufacturers making various kinds of top beauty and slimming equipment, including:
(1) Cavitation RF vacuum machine
(2) IPL (Intense Pulsed Light) Hair Removal machines
(3) RF (Radio Frequency) Skin Rejuvenation Systems
(4) No needle mesotherapy machine
(5) LED Skin Rejuvenation beauty machines
(6) Micro needle derma pen /derma roller
(7) Diamond and crystal microdermabrasion Systems
(8) Cryolipolysis cavitation rf machine
(9) Teeth whitening machine
(10) SPA capsules
(11) Provide OEM ODM service
We insist on the ideal of "technology innovation, professional manufacturer, and sincerely service" and the operating principle "customer priority, and mutual benefits". Quality is the soul of our company.
Our service
1. Warranty: We offer one year warranty
2. 24 hours on-line service.
3. OEM/ODM Service: Logo print according to customers' demand
4. If you buy machines from us, we will supply detailed user manual, video to you.
5. If you order large quantities, we will provide a very competitive price.
Feedback
FAQ
1. Is there any risk in 980 laser therapy? What problems will arise from improper treatment?
(1) Laser damage to the eyes, must avoid direct vision. (the patient should wear an eye mask, and the
operator can wear a transparent laser protective glasses, or not, as long as you do not look directly
at the laser.)
(2) Laser energy use is too large, will burn the skin, serious later may form pigmentation.
(3) Redness and blisters may occur if not properly handled or repaired.
(4) Scab usually occurs in the first two weeks after treatment, it is normal phenomenon, can fall off
naturally, it won't leave scar
Q2: For operators, how to avoid customer blister or redness?
(1) Therapeutic parameters must be gradually increased from small to large, with patience. Power is generally from 6W, pulse width from 30ms or 40ms, frequency from 2 or 3HZ. Maximum parameters: power no more than 12W, pulse width no more than 60ms, frequency no more than 3HZ.
(2) The treatment time should not be too long. Only one red blood filament can be done once, and it will be finished in a few minutes. Large area can be completed in three or four times.
(3)The same red blood filament cannot be scanned repeatedly. If it is not removed, it cannot do again.
Q3: Are blisters and scabs serious? Will it leave a scar? How to eliminate it?
Scab and blister (the blister that rises when doing) it is the result with bigger energy, when treating
thicker red blood silk, although parameter is correct also can have scab certainly, Never mind; Some clients use cosmetic for a long time to bring about corneous layer thin, also can rise easily a bit blisters, never mind, it won't leave scar. Ice dressing across sterile gauze. Maintain dry care can be good, soothe the user's mood.
Q4: Does it hurt? Do I need anesthetic?
When removing red blood silk, there is a slight tingling sensation, which can be tolerated by ordinary
people. Anesthesia is not recommended
Q5: What happens if the pulse width is too wide?
If the pulse width is too large, the skin will turn red after treatment.